您好,欢迎访问三七文档
时代广场用电设备容量Pjs=Kx·Ps(KW)Qjs=Pjs·tgφ(Kvar)Sjs=(P2js+Q2js)1/2或Sjs=Pjs/cosφ(KVA)Ijs=1000·Sjs/(31/2·UN)(A)式中:Pjs:有功计算负荷,KW;Qjs:无功计算负荷,Kvar;Sjs:视在计算负荷,KVA;Ijs:计算电流,A;Ps:用电设备的总容量,KW;Kx:需要系数;tgφ:用电设备功率因数的正切值;UN用电设备额定电压,V。设备计算负荷序号用电设备台数容总量Ps(KW)需要系数KxcosφtgφPjs(KW)Sjs(KVAIjs(A)1屋面风机171000.80.80.758060912热交换机291220.80.80.7598741123通风机17720.80.80.755843654排污泵461190.80.80.7595711075扶梯4300.80.80.752418276电梯141500.80.80.75120901367室内消火栓21800.80.80.751441081648生活水泵7640.80.80.755138589消防喷淋21800.80.80.7514410816410室外消火栓2440.80.80.7535264011喷淋稳压泵250.80.80.7543512风机盘管44716630.80.80.751330998151613防火卷帘门51410.80.80.7533253714景观照明606027315LED8080363总计6402913235616623158空调负荷计算序号用电设备台数单台容量(KW)需要系数Kxcosφtgφ计算负荷Pjs(KW)Qjs(Kvar)Sjs(KVA)Ijs(A)1单2711.30.80.80.752441833054632双1215.570.80.80.751560117019502963总计1521804135322553426E光照度式中u=0.75利用系数;uf=0.4维护系数K____减光系数(亦称维护系数),;n____灯的盏数;φ____每盏灯发出的光通量;φ=200A____受照房间面积。P=nφA/Euuf=40x200x84219/(2700x0.75x0.4)=832KW照明计算负荷照明面积84219㎡容量832(kw)Sjs=624KVA电流2836A8~15汽车库50~80剧场250~500演播厅40~70体育大中型:70~13050~80展览馆一般:40~80商业12~20中小学40~80办公20~40高等学校40~70旅馆40~70医院30~50公寓用电指标(W/m2)建筑类别用电指标(W/m2)建筑类别各类建筑物的用电指标计算和实际容量比较时代广场总建筑面积为:84219平方米其中:商场面积27471平方米P=0.035X56748=1986KWSjs=1489KVA备注:1#楼(6F-16F)3#楼(6F-22F)名称容量KVA备注设备总容量1662空调总容量2255照明总容量624其他总容量1489计算总容量6030变压器总容量6610
本文标题:负荷计算表格
链接地址:https://www.777doc.com/doc-4767029 .html