您好,欢迎访问三七文档
当前位置:首页 > 商业/管理/HR > 管理学资料 > PFEA111-PFEA112-for-tensiometer
WebTensionmeasurementWebTensionSystemswithTensionElectronicsPFEA111/112UserManual3BSE029380R0101enPressductor®Technology3BSE029380R01013BSE001264/BTemplate:3BSE001286/DUseofDANGER,WARNING,CAUTION,andNOTEThispublicationincludes,DANGER,WARNING,CAUTIONandNOTEinformationwhereappropriatetopointoutsafetyrelatedorotherimportantinformation.DANGERHazardswhichcouldresultinseverepersonalinjuryordeathWARNINGHazardswhichcouldresultinpersonalinjuryCAUTIONHazardswhichcouldresultinequipmentorpropertydamageNOTEAlertsusertopertinentfactsandconditionsAlthoughDANGERandWARNINGhazardsarerelatedtopersonalinjury,andCAUTIONhazardsareassociatedwithequipmentorpropertydamage,itshouldbeunderstoodthatoperationofdamagedequipmentcould,undercertainoperationalconditions,resultindegradedprocessperformanceleadingtopersonalinjuryordeath.Therefore,complyfullywithallDANGER,WARNING,andCAUTIONnotices.TRADEMARKSPressductor®isaregisteredtrademarkofABBAB.NOTICETheinformationinthisdocumentissubjecttochangewithoutnoticeandshouldnotbeconstruedasacommitmentbyABBAB.ABBABassumesnoresponsibilityforanyerrorsthatmayappearinthisdocument.InnoeventshallABBABbeliablefordirect,indirect,special,incidentalorconsequentialdamagesofanynatureorkindarisingfromtheuseofthisdocument,norshallABBABbeliableforincidentalorconsequentialdamagesarisingfromuseofanysoftwareorhardwaredescribedinthisdocument.ThisdocumentandpartsthereofmustnotbereproducedorcopiedwithoutABBAB’swrittenpermission,andthecontentsthereofmustnotbeimpartedtoathirdpartynorbeusedforanyunauthorizedpurpose.Thesoftwaredescribedinthisdocumentisfurnishedunderalicenseandmaybeused,copied,ordisclosedonlyinaccordancewiththetermsofsuchlicense.CE-MARKINGTheTensionElectronicsPFEA111/112fulfillstherequirementsasstatedintheEMCDirective89/336/EECandtheLowVoltageDirective73/23/EEC,providedthattheinstallationiscarriedoutinaccordancewiththeinstallationinstructionsgiveninChapter2Installation,includedinthisUserManual.TheTensionElectronicsPFEA111-20,PFEA111-65andPFEA112-20fulfilltherequirementsofsafetyapprovalforUSAandCanadaaccordingtothestandardUL61010C-1forProcessControlEquipmentandCSAC22.2No.1010-1SafetyRequirementsforMeasurement,ControlandLaboratoryUse,Part1:GeneralRequirementsCertificateNo.170304-E240621andNo.240504-E240621,providedthattheinstallationiscarriedoutinaccordancewiththeinstallationinstructionsgiveninChapter2Installation,includedinthisUserManual.Copyright©ABBAB,2007.TensionElectronicsPFEA111/112,UserManualTableofContents3BSE029380R0101iTABLEOFCONTENTSChapter1-Introduction1.1AboutthisManual...................................................................................................1-11.2HowtoUsethisManual..........................................................................................1-11.2.1GettingStarted........................................................................................1-11.2.2SavingActualDataandSettingsatCommissioning..............................1-11.3AboutthisSystem....................................................................................................1-21.4SafetyInstructions...................................................................................................1-31.4.1PersonnelSafety.....................................................................................1-31.4.2EquipmentSafety....................................................................................1-31.5TheMeasuringTechniqueBasedonPressductor‚Technology...............................1-4Chapter2-Installation2.1AboutthisChapter...................................................................................................2-12.2SafetyInstructions...................................................................................................2-12.3MountingtheLoadCells.........................................................................................2-12.4InstallingtheElectronicUnit...................................................................................2-22.4.1SelectingandRoutingtheCabling.........................................................2-22.4.1.1RecommendedCabling....................................................2-22.4.1.2Interference......................................................................2-42.4.1.3Synchronization...............................................................2-42.4.2MountingtheTensionElectronicsPFEA111/112..................................2-52.4.2.1IP65-version(NEMA4)..................................................2-52.4.2.2IP20-version(Unsealed)..................................................2-72.4.3Earthing...................................................................................................2-82.5InstallingMNSSelectFloorCabinet.......................................................................2-92.5.1MountingCabinetsTogether..................................................................2-92.5.2MountingCabinetstotheFloor..............................................................2-92.5.3SpaceRequ
本文标题:PFEA111-PFEA112-for-tensiometer
链接地址:https://www.777doc.com/doc-4500218 .html